  • Core Switch Link Aggregation Stacking

    Core Switch Link Aggregation Stacking

    Two common methods used to enhance switch deployments are: 1️⃣ Switch Stacking - Treats multiple physical switches as one logical switch for easier management. This allows servers or downstream switches to connect to multiple upstream switches for redundancy and load balancing, while managing only. Setting up an MLAG (Multi-Chassis Link Aggregation) between two Extreme XOS core switches involves several steps. After establishing the MLAG, you can connect edge switches, like the X435s, via LACP. Additionally, configuring SNTP (Simple Network Time Protocol) and ELRP (Extreme Loop Recovery. Huawei CE series switches support cluster switch system (CSS) technology (stacking of modular switches) and intelligent stack (iStack) technology (stacking of fixed switches). CSS and iStack have the following characteristics: 1. 1AX-2008 standard that defined LAG does not mention. In this tech paper, you will learn about the key protocols for building a redundant network and discover—based on five examples—how to design highly available three-tier or two-tier networks using LANCOM products.

    [PDF Version]
  • How to perform aggregation on a Layer 2 managed switch

    How to perform aggregation on a Layer 2 managed switch

    In order to configure 2 or more ports (up to 8) to be a port aggregate, simply navigate to Switching > Monitor > Switch ports and select the target ports, then choose "Aggregate". It is recommended that you do not have the target ports physically connected to anything during this. In this article, I'm going to describe how to set up Link Aggregation between two managed switches to provide connectivity, redundancy, and expanded bandwidth. The MS's LACP hashing algorithm uses traffic's source/destination IP, MAC, and port to determine which bonded link to utilize. This provides highly. Link aggregation, also called trunking, is an optional feature available on the Ethernet switch and is used with Layer 2 Bridging. The range of the LAG interface ID is 1 to 256. Configure IP addresses where appropriate.

    [PDF Version]
  • What type of switch should be used at the monitoring aggregation point

    What type of switch should be used at the monitoring aggregation point

    TAP aggregation switches link all of the monitoring devices to specific points in the network fabric that handle the packets that need to be observed. By bundling multiple network connections into a single high-bandwidth link, aggregation switches help. An Aggregation or "Top-of-Rack" switch is designed to connect everything in a rack at high speeds, then have an even bigger pipe out to the rest of the network. The Pro Aggregation does this with it's SFP28 25Gbps ports. For example, two 10-gigabit Ethernet ports, one each from two MLAG configured switches, can connect to two 10-gigabit ports on a host, switch, or network device to create a link that. Switch aggregation refers to the concept of consolidating multiple access layer switches into a single aggregation layer switch in a traditional three-tier network design. The aggregation layer serves as the convergence point for multiple access layer switches and is responsible for handling all. The In this deployment the Aggregation switch will have dual purposes, providing power and layer 2 access to wired devices and access points, while also aggregating downstream aggregation switches.

    [PDF Version]
  • How to Use Industrial Network Switches

    How to Use Industrial Network Switches

    Configure static routing or dynamic routing protocols such as OSPF and EIGRP according to the network topology. Set up an access control list (ACL) to restrict access to network traffic. Industrial network switches connect automation equipment, controllers, and other such devices. Learn about unmanaged, managed, and PoE enabled switches, as well as the differences between switches, routers, and hubs. Do you need PoE for cameras/APs? → Choose Industrial PoE/PoE++ Switch 2. Are you in rail/power/oil industry? →. Are you new to setting up industrial network switches and feeling overwhelmed? Don't worry, we've got you covered! In this comprehensive tutorial, we'll walk you through the process of setting up an industrial network switch from start to finish, making it easy for beginners to understand. When choosing a switch for an industrial environment, one of the most important decisions to make is whether to use a managed or unmanaged industrial Ethernet switch.

    [PDF Version]
  • How to insulate fiber optic cables outdoors

    How to insulate fiber optic cables outdoors

    For outdoor applications, use a ruggedized or direct burial cable if necessary. Any enclosures should offer reliable seals to keep moisture and critters out. Only use components from trustworthy manufacturers, and look for features that may help in certain environments. UV Exposure: Prolonged sunlight degrades standard plastic. To ensure the longevity and reliability of fiber optic cables in outdoor environments, it is crucial to protect them from various external factors. Here are detailed strategies for safeguarding these vital communication links: 1. Cable insulation has a functional purpose and is neither cosmetic nor secondary in nature. Rodents cause 5–8% of cable failures. Plan your outdoor fiber installation carefully by surveying the site, choosing the right cable type, and following FOA and OSP standards to ensure reliability. Select the best installation method—direct burial, aerial, conduit, or underwater—based on your environment and future network needs.

    [PDF Version]
  • How to install grounding wire on cable trays

    How to install grounding wire on cable trays

    Installation is very simple. First, you need to attach the terminal to the side wall of the tray, then pass the cable through its hole. In the place where the wire is in contact with the hole, insulation must be removed in the terminal. The metal in cable trays may be used as the EGC as per the limitations. Cable tray grounding wire is the safety connection that links your electrical system's cable tray to the ground. When designing a cable tray. The flexibility and scalability of cable trays make them an ideal choice for environments where cable density and organization can significantly impact operational efficiency. It is at this point that the voltage of.


  • How to wire the SPD in the distribution box

    How to wire the SPD in the distribution box

    Use AWG #10 stranded wire or larger (which is readily available and easily installed) to connect between the SPD and the breaker panel. In this blog, we'll walk you through a real-time installation of a Type 1 Surge Protection Device (SPD), giving you a first-hand look at the process. Surge Protection Devices are crucial components in ensuring the safety of electrical systems, especially in commercial and residential settings. more In this informative YouTube video, we. Surges may occur due to lightning strikes, power interruptions, or grid switching activities, causing a sudden spike in voltage that can damage devices, interrupt operations, and pose safety risks. The main purpose of an SPD is to redirect excess voltage safely to the ground, preventing harm to. Can you use one SPD for the whole building? You should put your SPD very close to the main busbar in the distribution box. The right setup keeps electronics. Drill and punch a hole in the SPD housing in a position to minimize the length of the connecting wires from the lugs of the SPD to the circuit breaker in the adjacent panel (or fused disconnect lugs). The connecting wires do not carry supply current.

    [PDF Version]
  • How to eliminate electrical discharge from network server racks

    How to eliminate electrical discharge from network server racks

    Grounding in a server rack refers to establishing a reliable electrical connection between the rack's components and the earth. This connection provides a safe pathway for electrical current dissipating into the ground, reducing the risk of electrical faults, equipment damage, or. Static-control flooring provides protection against electrostatic discharge (ESD) in multiple industries servicing disparate applications that range from eliminating annoying shocks to protecting aircraft flight-tower operations from equipment malfunctions. The whole structure consists of a metal circuit, a protect bus, and a ground wire. This article will delve. router → 1m patch cord → Cat6 FTP cable in the wall (both ends terminate in surface-mounted boxes with Cat6e keystones) → another 1m patch cord → switch → rest of the network. (i know it looks wonky, but that's the best i can do without destroying walls) Since switching to the FTP cable, whenever a.

    [PDF Version]